Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. med. biol. res ; 49(9): e5381, 2016. tab, graf
Article in English | LILACS | ID: lil-788948

ABSTRACT

Multi-center epidemiological studies must ascertain that their measurements are accurate and reliable. For laboratory measurements, reliability can be assessed through investigation of reproducibility of measurements in the same individual. In this paper, we present results from the quality control analysis of the baseline laboratory measurements from the ELSA-Brasil study. The study enrolled 15,105 civil servants at 6 research centers in 3 regions of Brazil between 2008–2010, with multiple biochemical analytes being measured at a central laboratory. Quality control was ascertained through standard laboratory evaluation of intra- and inter-assay variability and test-retest analysis in a subset of randomly chosen participants. An additional sample of urine or blood was collected from these participants, and these samples were handled in the same manner as the original ones, locally and at the central laboratory. Reliability was assessed with the intraclass correlation coefficient (ICC), estimated through a random effects model. Coefficients of variation (CV) and Bland-Altman plots were additionally used to assess measurement variability. Laboratory intra and inter-assay CVs varied from 0.86% to 7.77%. From test-retest analyses, the ICCs were high for the majority of the analytes. Notably lower ICCs were observed for serum sodium (ICC=0.50; 95%CI=0.31–0.65) and serum potassium (ICC=0.73; 95%CI=0.60–0.83), due to the small biological range of these analytes. The CVs ranged from 1 to 14%. The Bland-Altman plots confirmed these results. The quality control analyses showed that the collection, processing and measurement protocols utilized in the ELSA-Brasil produced reliable biochemical measurements.


Subject(s)
Humans , Adult , Laboratories/standards , Quality Control , Brazil , Longitudinal Studies , Observer Variation , Reference Standards , Reproducibility of Results
2.
Braz. j. med. biol. res ; 37(3): 295-299, Mar. 2004. tab
Article in English | LILACS | ID: lil-356615

ABSTRACT

Biotinidase deficiency is an inherited metabolic disorder characterized by neurological and cutaneous symptoms. Fortunately, it can be treated and the symptoms prevented by oral administration of the vitamin biotin. Using dried blood-soaked filter paper cards, biotinidase activity was determined in the sera of 225,136 newborns in Brazil. Mutation analysis performed on DNA from 21 babies with low serum biotinidase activity confirmed that 3 had profound biotinidase deficiency (less than 10 percent of mean normal sera biotinidase activity), 10 had partial biotinidase deficiency (10 to 30 percent of mean normal serum activity), 1 was homozygous for partial biotinidase deficiency, 4 were heterozygous for either profound or partial deficiency, and 3 were normal. Variability in serum enzyme activities and discrepancies with mutation analyses were probably due to inappropriate handling and storage of samples sent to the laboratory. Obtaining an appropriate control serum at the same time as that of the suspected child will undoubtedly decrease the false-positive rate (0.09 percent). Mutation analysis can be used to confirm the genotype of these children. The estimated incidence of biotinidase deficiency in Brazil is about 1 in 9,000, higher than in most other countries. Screening and treatment of biotinidase deficiency are effective and warranted. These results strongly suggest that biotinidase deficiency should be included in the newborn mass screening program of Brazil.


Subject(s)
Humans , Male , Female , Infant, Newborn , Biotinidase Deficiency/diagnosis , Mutation , Neonatal Screening , Brazil , Biotinidase Deficiency/epidemiology , Biotinidase Deficiency/genetics , Genotype , Incidence
SELECTION OF CITATIONS
SEARCH DETAIL